Skip to content

Alpha Boiler Fault Codes / Error Codes List

Boilers
Mo Alwadi
Mo Alwadi , Gas Safe Registered Engineer

Updated:

Alpha Boiler Fault Codes / Error Codes List

Alpha boiler fault codes help identify heating and hot-water issues—from ignition failure and low water pressure to overheating or fan faults—so you know what the display means and when to call a qualified engineer.

In this guide, the Gas Safe registered heating team at Let’s Heat lists common Alpha boiler error codes across the E-Tec, E-Tec Plus, Evoke, Regular, and Protec Plus ranges, alongside flashing light meanings and safe next steps. For a wider overview of models and warranties, see our Alpha Boilers guide. 

Quick Summary: Most Common Alpha Boiler Fault Codes

  • 01 / E01: Ignition failure (no flame detected — Gas Safe engineer required).

  • 10 / E10: Low primary system pressure (check pressure gauge and manual; look for leaks if it keeps dropping).

  • 02 / 25: Overheat boiler lockout (restricted flow, air in the system, or pump issue).

  • 16: Fan fault (fan or wiring issue — Gas Safe engineer required).

Legal Disclaimer: Professional Repair Only

It is important to note that attempting to fix your Alpha boiler on your own is both illegal and dangerous. Only a Gas Safe registered engineer is authorised to work on gas appliances. This guide is meant to provide diagnostic information to help you communicate effectively with professionals and understand potential repair costs.

General Alpha Boiler Error/Fault Codes

Below is a table of the most common fault codes encountered in Alpha boilers, along with descriptions of the issues they represent.

Common Fault Codes and Descriptions

Fault CodeFaultDescription
1Ignition failurePossible causes: issues with gas supply, pressure tubes, ignition electrode, flame sensor, gas valve, or PCB (Printed Circuit Board).
2Overheat boiler lockoutCaused by a blocked heat exchanger, air in the system, pump issues, or thermostat problems.
3High flue thermostat temperatureIndicates restricted primary flow, blocked heat exchanger, or flue issues.
4Gas valve electrical faultRelated to faulty wiring connections or gas valve.
5Heating flow sensor faultIssues with flow sensor wiring or sensor failure.
6Domestic hot water (DHW) sensor faultFaulty wiring or sensor malfunction in the DHW system.
8Maximum number of resetsIndicates repeated attempts to reset the boiler have failed. Review fault history for more information.
10Low primary system pressureOften due to leaks, faulty pressure relief valves, or insufficient expansion vessel pressure.
12Cylinder sensor fault (FlowSmart only)Indicates a fault in cylinder sensor wiring or sensor malfunction.
15Internal wiring errorInvolves issues with internal wiring connections to the PCB.
16Fan faultRelated to faulty fan or its wiring connections.
20Flame sensing faultFault in flame sensing electrode or related wiring.
24Control panel button faultUsually caused by jammed buttons on the control panel or PCB.
25Overheat lockoutCaused by air in the heat exchanger or restricted flow within the system.
27Insufficient primary flowPossible blockages in the system, air in the heat exchanger, or pump issues.
29Flue sensor faultIndicates faulty flue sensor or related wiring issues.
31Communication loss with external controlInvolves issues with remote control or receiver connection.
37Low supply voltageCheck the main power supply for irregularities.
38, 43Loss of flame rectificationPotential gas supply issues or problems with flame sensing components.
44Safety lockoutCaused by thermostat issues or hot tap requests being processed too quickly.
46External sensor interventionOften caused by external sensor damage or faulty connections.
47Reduced burner outputIndicates airflow restrictions, heat exchanger issues, or pump faults.
51Climatic RF communication faultRelated to communication issues between the boiler and the climatic control unit.
Heating engineer using a multimeter to troubleshoot Alpha boiler fault codes and pressure gauge
Troubleshooting Alpha E-Tec, Evoke, and Protec Plus fault codes and flashing warning lights in a UK home with Let’s Heat.

Alpha E-Tec, E-Tec Plus, Evoke Combi Boiler Error/Fault Codes

Specific Error Codes for E-Tec Models

Fault CodeFaultDescription
60Pump errorEither the pump is stuck or there is an electrical fault. The pump may need freeing, or replacement may be required.
61Air in pumpThis is due to restricted central heating flow, improper system pressure, or valves being closed.
70Return/flow sensor faultSensor wiring issues or faulty sensor resistance are likely causes.
75/76Return/flow sensor failureBoth sensors may need to be inspected for potential failures.
SRService reminderIndicates that the service countdown has reached 0, but the boiler will continue working.

Alpha E-TEC Regular Gas Boiler Error Codes

Common Fault Codes for Regular Gas Boilers

Fault CodeFaultDescription
1Ignition failurePossible issues include problems with the gas supply, ignition electrode, or flame sensor.
2Overheat boiler lockoutCaused by blocked heat exchangers, pump failures, or air trapped in the system.
3High flue thermostat temperatureIndicates restricted flow or blocked heat exchangers.
4Gas valve electrical connection faultFault in gas valve wiring or a faulty PCB.
5Heating flow sensor faultIssues with flow sensor wiring or malfunctioning sensor.
6Internal wiring errorIndicates incorrect wiring configurations or internal PCB faults.
7Chimney sweep function activeThe chimney sweep function is active and needs to be disabled.
16Fan faultIndicates a problem with fan wiring or fan malfunction.
27Insufficient primary flowBlocked flow, air in the heat exchanger, or pump faults are common causes.
44Safety lockoutTriggered by faulty thermostat requests or rapid on/off hot tap commands.

Alpha Protec Plus System Error Codes

Fault Codes Specific to Protec Plus Systems

Fault CodeFaultDescription
0A1Ignition failureCould be caused by gas supply issues or spark electrode faults.
0A2Flame detection faultIndicates issues with flame sensing electrode connections.
0A3Overheat thermostat lock-outCaused by overheating in the primary heating circuit, restricted water circulation, or a faulty overheat thermostat.
0A5Fan speed faultFlue/ventilation problems or fan wiring issues.
0A7High flue temperature faultCould be caused by air in the heat exchanger or system restrictions.
0A9Gas valve electrical errorIndicates a fault in valve connections or PCB.
0A15Flow and return sensor anomalyDetected abnormal temperature changes in the flow/return sensor.
0A30Flow sensor short circuitIndicates flow sensor wiring or connections need attention.
0A31Flow sensor out of rangeThe flow sensor is detecting a temperature outside the normal range.
0A37Insufficient system flowThe system flow is too low, likely due to restrictions or pump issues.
0A43Return sensor short circuitCaused by damaged return sensor wiring or connections.

 

Alpha Flashing Light Error Codes

Understanding Flashing Lights on Alpha Boilers

Alpha boilers use a flashing light sequence to indicate specific problems. Below are common flashing light sequences and their meanings:

Light SequenceFaultDescription
No lights onElectricity faultIndicates no power supply to the boiler.
Red A or BBurner has failed to igniteRotate selector switch to the reset position and try again.
Yellow B or CBurner is litNo action required.
Flashing yellow or green DElectrical supply is onNo action required.
Flashing red A or BTemperature sensor faultContact a Gas Safe engineer.
Red and yellow flashingPump fault or restricted flowA Gas Safe engineer should check the pump and system.

Final Thoughts: Boiler Maintenance and Warranty

Regular maintenance is essential for the long-term reliability of your Alpha boiler. Schedule an annual service to keep warranty conditions valid and spot developing issues early.

If faults keep returning and repairs are no longer cost-effective, replacing the boiler may be the smarter long-term option. Always prioritise safety and never remove the boiler casing or attempt internal gas repairs yourself.

If your Alpha boiler keeps showing a fault code across Cardiff, Newport, Bristol, or South Wales, our Gas Safe registered engineers (Registration No. 977042) can help. Whether you need boiler repairs, urgent emergency boiler repair, or want to weigh up a replacement with a free new boiler quote, call Let’s Heat on 0330 174 6700 or visit our Contact Us page.

Frequently Asked Questions About Alpha Boiler Fault Codes

What does E01 mean on an Alpha boiler?

Error E01 indicates an ignition failure—meaning the boiler could not detect a flame when trying to light the burner. Common causes include gas supply, ignition electrode, or flame sensor faults, which require a Gas Safe engineer.

Why is my Alpha boiler flashing red?

A flashing red light on the A indicator usually signals an overheat thermostat fault (often alongside code 2, 25, or 0A3). Switch off the demand and contact a Gas Safe registered engineer to inspect the cause safely.

What does fault code 10 (E10) mean on an Alpha boiler?

Fault code 10 (or E10) indicates low primary water pressure in the heating system. Check the pressure gauge against your manual; if the pressure keeps dropping after topping up, contact a Gas Safe engineer to check for leaks or a faulty pressure relief valve.

Can I reset my Alpha boiler myself?

Yes, you can try a single reset following your exact model’s user manual (for example, turning the selector switch to the reset position). Avoid repeated resets—too many attempts can trigger fault code 8—and call a Gas Safe engineer if the error returns.

Mo Alwadi

Mo Alwadi (Gas Safe Registered Engineer)

Mo Alwadi is Renewable Manager at Let’s Heat and a Gas Safe registered engineer (registration no. 977042), with experience in domestic heating and air conditioning. He contributes technical guidance on boiler installation, boiler replacement, heating systems, air conditioning and home energy solutions, helping UK homeowners understand their options and make informed decisions.

View all posts by Mo Alwadi →
Need help? Chat on WhatsApp